EEG: Electroencephalography
Full Line of Electroencephalography Acquistion & Analysis Solutions for Human & Animal Research
Fully automated routines provide quick, easy and reproducible results
Record up to 32 channels of wireless and logged EEG data.
Surface and Implanted EEG Solutions
BIOPAC® provides a wide range of tools for recording, displaying, and analyzing surface EEG (sEEG) and implanted EEG signals from human and animal subjects. BIOPAC® offers a number of hardware solutions that allow you to record from a single channel of EEG and up to 32 channels of wireless and logged data. There are also hardware options available for full-band EEG (FbEEG) recordings with bandwidths from DC to hundreds of Hz. EEG Systems are available for in lab recordings, real-world applications, small animal wireless recordings, and MRI applications. Advanced real-time analysis options provide metrics for subject engagement, workload and drowsiness.
Try EEG tools in the free AcqKnowledge Demo
See More...Hardware Packages | EEG: Electroencephalography
Hardware Bundles are complete solutions for the specified application. Choose your preferred platform and bundle, then click "Request Pricing" to request an estimate, add/remove items, or complete purchase. If you have questions about specific items, click through to the product web page for details and specifications, or contact your Local Sales contact.
Wired
-
EEG Amp & Cap
Wired | EEG: Electroencephalography
EEG amp with electrode cap system
-
MP36R System plus leads & reusable 8 mm electrodes
Wired | EEG: Electroencephalography
MP36R with AcqKnowledge plus lead set, reusable 8 mm snap electrode & gel
-
MP36R System plus 8 mm electrodes
Wired | EEG: Electroencephalography
MP36R with AcqKnowledge plus electrode lead adapter, 8 mm shielded TP electrode and 8 mm unshielded TP electrode
-
MP160 System plus five EEG amps & 10/20 EEG Cap System
Wired | EEG: Electroencephalography
MP160 with AcqKnowledge plus five EEG amps & Touch proof 10/20 EEG Cap System
EEG Amp & Cap
- 1 x EEG Electroencephalogram Amplifier
- 1 x Electrode Cap Sys., TouchProof
- 1 x Module Extension Cables
- 1 x Abrasive Pads 10/pk
- 1 x Electrode Impedance Checker
MP36R System plus leads & reusable 8 mm electrodes
- 1 x MP36R Systems
- 1 x Ag-AgCl Reusable Snap Electrodes
- 1 x Lead set, shielded, BSL
- 1 x Tensive Adhesive Gel, 33 ml
- 1 x Abrasive Pads 10/pk
MP36R System plus 8 mm electrodes
- 1 x MP36R Systems
- 2 x Ag-AgCl Electrodes
- 1 x Ag-AgCl Electrodes
- 1 x Electrode Lead Adapter, TP
- 1 x Tensive Adhesive Gel, 33 ml
- 1 x Abrasive Pads 10/pk
MP160 System plus five EEG amps & 10/20 EEG Cap System
- 1 x MP160 Data Acquisition Systems
- 5 x Module Extension Cables
- 5 x EEG Electroencephalogram Amplifier
- 1 x Electrode Cap Sys., TouchProof
- 1 x Abrasive Pads 10/pk
- 1 x Electrode Impedance Checker
Wireless
-
B-Alert X10 Wireless EEG & Cognitive State Metrics with AcqKnowledge
Wireless | EEG: Electroencephalography
X10 Wireless EEG (9 CH) and ECG plus Cognitive State Metrics and current release AcqKnowledge software
-
MP160 System + Wireless EEG with reusable electrodes
Wireless | EEG: Electroencephalography
MP160 with AcqKnowledge plus wireless EEG BioNomadix transmitter/receiver set, lead, reusable 8 mm snap electrodes, and impedance checker
-
BioNomadix Logger with EEG setup
Wireless | EEG: Electroencephalography
BioNomadix Logger plus one transmitter for wireless EEG setup
B-Alert X10 Wireless EEG & Cognitive State Metrics with AcqKnowledge
- 1 x Unknown Product (Array)
MP160 System + Wireless EEG with reusable electrodes
- 1 x MP160 Data Acquisition Systems
- 1 x BioNomadix 2Ch Wireless EEG Amplifier
- 1 x Electrode Leads - BioNomadix Wireless
- 1 x Electrode Leads - BioNomadix Wireless
- 1 x Ag-AgCl Reusable Snap Electrodes
- 1 x Ten20 Conductive Paste 114 g
- 1 x Abrasive Pads 10/pk
- 1 x Electrode Impedance Checker
BioNomadix Logger with EEG setup
- 1 x BioNomadix Wireless Wearable Physiology Logger
- 1 x Electrode Leads - BioNomadix Wireless
- 1 x Electrode Leads - BioNomadix Wireless
- 1 x Ag-AgCl Reusable Snap Electrodes
- 1 x Tensive Adhesive Gel, 33 ml
- 1 x Abrasive Pads 10/pk
- 1 x Electrode Impedance Checker
MRI
-
MP160 System + EEG Amp with disposable RT electrodes
MRI | EEG: Electroencephalography
MP160 with AcqKnowledge plus EEG Amp for MRI with filtered cable set and disposable radio-translucent electrodes
MP160 System + EEG Amp with disposable RT electrodes
- 1 x MP160 Data Acquisition Systems
- 1 x MRI Filtered Cable Sets
- 3 x Leads - RT for MRI
- 1 x Electrode Gels
- 1 x Electroencephalogram EEG Amplifier for MRI
- 1 x Disp. RT Dry Electrode for EDA, 100/pk
- 1 x Abrasive Pads 10/pk
- 1 x Electrode Impedance Checker
Animal
-
Implantable EEG
Animal | EEG: Electroencephalography
EPOCH implantable EEG system with MP160 System for long-term wireless EEG/neural signal monitoring for rats, mice, or pups
-
MP36R System plus leads & 12 mm needle electrodes
Animal | EEG: Electroencephalography
MP36R with AcqKnowledge plus electrode lead adapter and three 12 mm TP unipolar needle electrodes
-
Stellar | AcqKnowledge Intuitive Animal Scheduler License
Animal | EEG: Electroencephalography
Schedule, Record, and Analyze Stellar Telemetry Data with AcqKnowledge
Implantable EEG
- 1 x Unknown Product (Array)
- 1 x Unknown Product (Array)
- 1 x EPOCH Transmitter Activation Utility
MP36R System plus leads & 12 mm needle electrodes
- 1 x MP36R Systems
- 3 x Needle Electrodes - Animal/Tissue
- 1 x Electrode Lead Adapter, TP
Stellar | AcqKnowledge Intuitive Animal Scheduler License
- 1 x Unknown Product (Array)
Details
Available BIOPAC® EEG solutions include:
- BioNomadix® Dual-Channel Wireless EEG Amplifiers with the MP160 System
- B-Alert 9 Channel Wireless EEG System with Cognitive States Analysis
- Mobita® 32 channel Wearable EEG system (wireless live or logged data)
- EEG100C Tethered amplifiers with spot electrodes, or electrode caps and the MP160 System
- EEG100C-MRI amplifiers with spot electrodes with cable/filter sets and the MP160 System
- Epoch Wireless 2 Channel EEG System for small animals used with the MP160 System
Powerful AcqKnowledge® software is include with MP160, B-Alert, and Mobita system options.
AcqKnowledge® displays the data in a variety of formats for quick and easy viewing. On-line calculation channels allow you to configure channels and filter data using FIR and IIR filters to provide optimal signals for analysis and create custom EEG montages.
A range of fully-automated routines provide quick, easy, and reproducible results.
Videos
Support
Application Notes
- 154 - High Level Transducer Connections - HLT100C
- 159 - Hand Switch and Foot Switch - TSD116 Series
- 186 - Variable Assessment Transducer - TSD115
- 110 - Amplifier Baseline Offset Adjustment
- 136 - Battery Pack Instructions - BAT100
- 162 - Stimulation Features of MP160/150/100 Systems
- 185 - iMac and G3 Compatibility Issues
- 195 - MP System Data Sampling Reference
- 207 - UDP Install: MP150 + No Network Access
- 208 - UDP Install: MP150 + Domain Network Access
- 209 - UDP Install: MP150 + Network Access or Multiple Computers
- 105 - Auditory Brainstem Response (ABR) Testing
- 121 - Waveform Data Reduction
- 122 - Power Spectrum Analysis
- 131 - Averaging Mode in the MP System
- 143 - Importing AcqKnowledge Data Into Excel
- 155 - AcqKnowledge File Formats for the Macintosh
- 156 - AcqKnowledge File Formats for PC With Windows
- 191 - Digital I/O Channels
- 200 - Creating Arbitrary Waveforms for the MP Systems Stimulator
- 204 - AcqKnowledge Peak Detector Operation
- 211 - EEG Analysis With AcqKnowledge
- 218 - Hardware API
- 219 - Known Issues - AcqKnowledge
- 226 - BIOPAC Software Compatibility on Mac-Intel Core Duo Machines
- 102 - Biopotential Amplifier Testing With CBLCAL
- 001 - AcqKnowledge Release and OS Compatibility
Knowledge Base
- * CLEANING GUIDELINES *
- AC mode
- AcqKnowledge accuracy
- AcqKnowledge backwards compatibility
- Amplifier baseline offset adjustment
- Amplifier conversion - 2 mm to touchproof
- Arbitrary waveform stimulation
- Audio recording synchronization
- Band-pass and band-stop filters
- Biopotential amplifier signal validation
- Bipolar EEG
- Buffer overflow
- Calculating file sizes
- CAP100C electrode connections
- Combining Video with AcqKnowledge
- Common mistakes/general troubleshooting
- Connecting the TSD116C Switch Box
- Copy and paste append markers along with data
- Duplicating waveforms
- Editing noisy data
- EEG frequency bands
- EEG reference - linked ears, summed ears, etc.
- Electrode Properties - gel and adhesive
- Excel files exported from BIOPAC software open in Excel 'Protected View'
- Exporting Data to SPSS
- External Devices and Channel Contention
- Extracting data segments from a file
- Ground vs. reference for EEG recording
- Grounding guidelines
- High pass filters
- IIR vs. FIR filters
- Interfacing third-party transducers
- LabView interface
- Low pass filters
- Maximum number of channels for EEG
- MP150 UDP protocol fixed IP address
- MRI - Triggering
- Notch filter
- Optimal ground placement
- Outputting a signal through the STM100C
- Physiological measurements - life science signals using BIOPAC
- PPG setup and calibration
- Railing signal (flatline)
- Recording good data
- Text files - import and export
- Upgrading from PCMCIA to USB
- USB Drivers and Controller Communication
- Using other software with BIOPAC hardware
- Visual presentation system triggering the MP150/100
Stay Connected